Santwell is a load cell company specializing in R&D, production and sales of high precision weighing sensor products.
Ningbo Santwell Import & Export Co., Ltd relying on strong innovation ability and firm R&D perseverance, successfully developed Precision Alloy Steel Cells Double-Ended shear beam load cell High Quality Double Ended Beams load cell 20T QSK. High-end technologies are used to manufacture Precision Alloy Steel Cells Double-Ended shear beam load cell High Quality Double Ended Beams load cell 20T QSK.The product can play out its greatest effect in the field(s) of Force Sensors & Load Cells. Santwell has been dedicated to the design, R&D, manufacturing, and updates of Load cells, Subminiature force transducers, miniature load cells, Intelligent load cells. We fully hope that we can satisfy customers from different fields, countries, and regions by offering them high-quality products and professional service. If you have any questions or problems, please contact us at any time through the contact information listed on our website.
Model Number: | QSK | Place of Origin: | Zhejiang, China |
Brand Name: | Santwell | Usage: | PRESSURE SENSOR |
Theory: | Resistance Sensor | Output: | Analog SENSOR |
Description: | double ended beam load cell | Rated Load: | 20 t |
Sensitivity: | 2.0000±0.002mv/v | Total Error: | ±0.02%F.S |
Creep(30 minutes): | ±0.02%F.S | Recommended Excitation Voltage: | 5V-18V(AC or DC) |
Maximum Excitation Voltage: | 24V(AC or DC) | Zero Balance: | ±1%F.S |
Insulation Impedance: | ≥5000MΩ | Safe Overload: | ±150%F.S |
UItimate Overload: | ±200%F.S | Application: | material tank scales dry mortar tank |
Technical Parameter | ||||
Rated Load | T | 20 | ||
Sensitivity | mV/V | 2.0000±0.002 | ||
Total Error | %F.S | ±0.02 | ||
Creep(30minutes) | %F.S | ±0.02 | ||
Recommended Excitation Voltage | V | 5 ~18 (AC or DC) | ||
Maximum Excitation Voltage | V | 24 (AC or DC) | ||
Zero Balance | %F.S | ±1 | ||
Input Impedance | Ω | 775±10 | ||
Output Impedance | Ω | 700±5 | ||
Insulation Impedance | MΩ | ≥5000 | ||
Safe Overload | %F.S | 150 | ||
Ultimate Overload | %F.S | 200 | ||
Operating Temperature Range | ℃ | (-30~+70) | ||
Compensated Temperature Range | ℃ | (-20~+60) | ||
Temperature Effect On Load | ℃ | ±0.02%F.S/10 | ||
Temperature Effect On Zero | ℃ | ±0.02%F.S/10 | ||
Construction | Alloy steel | |||
Protection Class | IP67&IP68 | |||
Citation | GB/T7551-2008/OIML R60 | |||
Mode of Connection | Input+E:Red Input-E:Black Output+S:Green Output-S:White |