Santwell is a load cell company specializing in R&D, production and sales of high precision weighing sensor products.
Having invested a great deal of funds to technology research and product development,Ningbo Santwell Import & Export Co., Ltd has successfully worked out Qskl High Precision Aluminum Steel Double Ended shear beam load cell QSKL. Based on scientific strategic decision-making, driven by strong operating capabilities, and driven by technology and R&D capabilities, the products developed and manufactured have clear positioning and goals. Ningbo Santwell Import & Export Co., Ltd adhere to the corporate philosophy of 'people orientation' and always advocate honesty, innovation, and fairness. We hope to occupy an important position in the industry and become one of the most leading brands in the future.
Model Number: | QSKL | Place of Origin: | Zhejiang, China |
Brand Name: | Santwell | Usage: | PRESSURE SENSOR |
Theory: | Resistance Sensor | Output: | Analog SENSOR |
Description: | double ended beam load cell | Rated Load: | 3~6T |
Sensitivity: | 2.0000±0.002mv/v | Total Error: | ±0.02%F.S |
Creep(30 minutes): | ±0.02%F.S | Recommended Excitation Voltage: | 5V-18V(AC or DC) |
Maximum Excitation Voltage: | 24V(AC or DC) | Zero Balance: | ±1%F.S |
Insulation Impedance: | ≥5000MΩ | Safe Overload: | ±150%F.S |
UItimate Overload: | ±200%F.S | Application: | batching scale concrete mixing station |
Technical Parameter | ||||
Rated Load | T | 3~6 | ||
Sensitivity | mV/V | 2.0000±0.002 | ||
Total Error | %F.S | ±0.02 | ||
Creep(30minutes) | %F.S | ±0.02 | ||
Recommended Excitation Voltage | V | 5 ~18 (AC or DC) | ||
Maximum Excitation Voltage | V | 24 (AC or DC) | ||
Zero Balance | %F.S | ±1 | ||
Input Impedance | Ω | 775±10 | ||
Output Impedance | Ω | 700±5 | ||
Insulation Impedance | MΩ | ≥5000 | ||
Safe Overload | %F.S | 150 | ||
Ultimate Overload | %F.S | 200 | ||
Operating Temperature Range | ℃ | (-30~+70) | ||
Compensated Temperature Range | ℃ | (-20~+60) | ||
Temperature Effect On Load | ℃ | ±0.02%F.S/10 | ||
Temperature Effect On Zero | ℃ | ±0.02%F.S/10 | ||
Construction | Aluminum | |||
Protection Class | IP67&IP68 | |||
Citation | GB/T7551-2008/OIML R60 | |||
Mode of Connection | Input+E:Red Input-E:Black Output+S:Green Output-S:White |