Santwell is a load cell company specializing in R&D, production and sales of high precision weighing sensor products.
Ningbo Santwell Import & Export Co., Ltd In-depth analysis of the actual needs of target customers, combined with its own advantages resources, successfully developed 100Kg~1000Kg Black Orange Aluminum Alloy 100Kg 300Kg 500Kg Digital Hanging Hook Scale. High-end technologies helps us ensure 100Kg~1000Kg Black Orange Aluminum Alloy 100Kg 300Kg 500Kg Digital Hanging Hook Scale quality, improve manufacturing efficiency, and reduce manpower input. It has extensive uses in the field(s) of Weighing Scales. The design is the most striking aspect of Santwell. Its design comes from our designers who are sensitive to fashion and are know the commercial needs of the market very well. Also, Load cells, Subminiature force transducers, miniature load cells, Intelligent load cells made of well-selected raw materials.
Place of Origin: | Zhejiang, China | Brand Name: | Santwell |
Model Number: | HK | Accuracy Class: | Chinese GB/T 11883 - 2002 Class III |
Tare Range: | 100% F.S. | Auto Zero: | ±50% F.S. |
Manual Zero: | ±2% F.S. | Zero-tracking: | 0.5e/s |
Reading Stable Time: | < 10 seconds | Auto-sleep: | Sable and no action in 3 sec. |
Accuracy Class | Chinese GB/T 11883 - 2002 Class III |
Tare Range | 100% F.S. |
Auto Zero | ±50%F.S. |
Manual Zero | ±2% F.S. |
Zero-tracking | 0.5e/s |
Reading Stable Time | < 10 seconds |
Auto-sleep | Sable and no action in 3 sec. |
Auto-off | Sable and no action in 3 min. |
Overload | 100% F.S.+9e |
Max .Safety Load | 120% F.S. |
Ultimate Load | 300% F.S. |
Battery Life | > 1 50 hours |
Temp.(Op.) | 10 °C~ +40°C |
Humidity(Op,) | < 90% at 20°C |
Symptom | Possible Causes | Solution |
blank display when On/Offis pressed | discharged battery | replace battery |
defective battery | ||
defective ON/OFF key | press ON/OFF key for long | |
no action taken after TARE or HOLD is pressed | defective TARE or HOLD key | clean TARE or HOLD key |
unstable readings | scale in motion | stabilize the load and scale |
scale in damped | dry the scale | |
dust on PCS board | clean PCB board | |
reading is not zero without load | unstable system power | longer warm-up time |
load-cell stressed too much or too long | hang the scale in storage | |
large error in weight reading | scale is not zeroed before loading | keep the scale unload and reboot |
re-calibration nee ded | re-calibration the scale | |
improper unit | switch to proper unit |
Model | Max.Cap(kg/1b) | E(kg/lb) | Division(n) |
OCS-C | 100/200 | 0.02/0.04 | 5,000 |
OCS-C . | 200/440 | 0.05/0.11 | 4. ,000 |
OCS-C | 300/660 | 0.10/0.22 | 3 ,000 |
OCS-D | 100/200 | 0.02/0.04 | 5,000 |
OCS-D | 200/440 | 0.05/0.11 | 4,000 |
OCS-D | 300/600 | 0.10/0.22 | 3,000 |
OCS-D | 500/1110 | 0.20/0.44 | 2 ,500 |
QUICK LINKS