Santwell is a load cell company specializing in R&D, production and sales of high precision weighing sensor products.
Santwell has a collection of Solid Structure 300Kg 100Kg 1000Kg Black Orange Aluminum Alloy Industrial Broiler Custom Hanging Scale available from manufacturers around the world so if you'd like to buy some, do give a look. Ningbo Santwell Import & Export Co., Ltd offers a high standard of service together with being competitively priced. Ningbo Santwell Import & Export Co., Ltd will provide high-quality services, and bring customers a better experience. In this way, the company can continue to strengthen its future strength in technological innovation and strive to create complete products Ecological chain.
Place of Origin: | Zhejiang, China | Brand Name: | Santwell |
Model Number: | HK | Accuracy Class: | Chinese GB/T 11883 - 2002 Class III |
Tare Range: | 100% F.S. | Auto Zero: | ±50% F.S. |
Manual Zero: | ±2% F.S. | Zero-tracking: | 0.5e/s |
Reading Stable Time: | < 10 seconds | Auto-sleep: | Sable and no action in 3 sec. |
Accuracy Class | Chinese GB/T 11883 - 2002 Class III |
Tare Range | 100% F.S. |
Auto Zero | ±50%F.S. |
Manual Zero | ±2% F.S. |
Zero-tracking | 0.5e/s |
Reading Stable Time | < 10 seconds |
Auto-sleep | Sable and no action in 3 sec. |
Auto-off | Sable and no action in 3 min. |
Overload | 100% F.S.+9e |
Max .Safety Load | 120% F.S. |
Ultimate Load | 300% F.S. |
Battery Life | > 1 50 hours |
Temp.(Op.) | 10 °C~ +40°C |
Humidity(Op,) | < 90% at 20°C |
Symptom | Possible Causes | Solution |
blank display when On/Offis pressed | discharged battery | replace battery |
defective battery | ||
defective ON/OFF key | press ON/OFF key for long | |
no action taken after TARE or HOLD is pressed | defective TARE or HOLD key | clean TARE or HOLD key |
unstable readings | scale in motion | stabilize the load and scale |
scale in damped | dry the scale | |
dust on PCS board | clean PCB board | |
reading is not zero without load | unstable system power | longer warm-up time |
load-cell stressed too much or too long | hang the scale in storage | |
large error in weight reading | scale is not zeroed before loading | keep the scale unload and reboot |
re-calibration nee ded | re-calibration the scale | |
improper unit | switch to proper unit |
Model | Max.Cap(kg/1b) | E(kg/lb) | Division(n) |
OCS-C | 100/200 | 0.02/0.04 | 5,000 |
OCS-C . | 200/440 | 0.05/0.11 | 4. ,000 |
OCS-C | 300/660 | 0.10/0.22 | 3 ,000 |
OCS-D | 100/200 | 0.02/0.04 | 5,000 |
OCS-D | 200/440 | 0.05/0.11 | 4,000 |
OCS-D | 300/600 | 0.10/0.22 | 3,000 |
OCS-D | 500/1110 | 0.20/0.44 | 2 ,500 |