Our R&D engineers applied the technology to the manufacturing of this kind of product.With those approved performances, the product can be widely found in the field(s) of Force Sensors & Load Cells.
In this era, it is necessary for any enterprise including Ningbo Santwell Import & Export Co., Ltd to improve our R&D strength and develop new products on a regular basis. QS-X 10 20 30 T Specialized Customized Production Alloy Steel Weighbridge 10 Ton Load Cell has made great technological breakthroughs because technicians often hold training and technical exchanges to improve professional skills. Ningbo Santwell Import & Export Co., Ltd have long desired to become one of the most influential enterprises in the industry. At present, we are busy improving our capabilities in product manufacturing, and gathering talents especially technical talents to develop our own core technologies.
Model Number: | QS-ZX | Type: | Load Cell |
Place of Origin: | Zhejiang, China | Brand Name: | santwell |
Usage: | truck scale | Theory: | resistan |
Output: | Resistance strain | Description: | Double ended shear beam load cell |
Rated Load: | 10/20/30 T | Sensitivity: | 2.0000±0.002mV/V |
Total Error: | ±0.02%F.S | Creep(30 minutes): | ±0.02%F.S |
Recommended Excitation Voltage: | 5V~18V(AC or DC) | Maximum Excitation Voltage: | 24V(AC or DC) |
Zero Balance: | ±1%F.S | Insulation Impedance: | ≥5000MΩ |
Safe Overload: | 150%F.S | Ultimate Overload: | 200%F.S |
Technical Parameter | ||||
Rated Load | T | 10/20/30 | ||
Sensitivity | mV/V | 2.0000±0.002 | ||
Total Error | %F.S | ±0.02 | ||
Creep(30minutes) | %F.S | ±0.02 | ||
Recommended Excitation Voltage | V | 5 ~18 (AC or DC) | ||
Maximum Excitation Voltage | V | 24 (AC or DC) | ||
Zero Balance | %F.S | ±1 | ||
Input Impedance | Ω | 775±10 | ||
Output Impedance | Ω | 700±5 | ||
Insulation Impedance | MΩ | ≥5000 | ||
Safe Overload | %F.S | 150 | ||
Ultimate Overload | %F.S | 200 | ||
Operating Temperature Range | ℃ | (-30~+70) | ||
Compensated Temperature Range | ℃ | (-20~+60) | ||
Temperature Effect On Load | ℃ | ±0.02%F.S/10 | ||
Temperature Effect On Zero | ℃ | ±0.02%F.S/10 | ||
Construction | Alloy steel | |||
Protection Class | IP67&IP68 | |||
Citation | GB/T7551-2008/OIML R60 | |||
Mode of Connection | Input+E:Red Input-E:Black Output+S:Green Output-S:White |