Double Ended shear beam load cell weight sensor 10 ton load cell 20 Ton To 120 Ton QSF is carefully researched and developed by the R&D team, and the positioning is very clear, which is to solve the pain points of customers and meet the needs of customers.Therefore,the measured data indicates that the product meets the market requirements.
Ningbo Santwell Import & Export Co., Ltd has been manufacturing, exporting and supplying excellent quality Double Ended shear beam load cell weight sensor 10 ton load cell 20 Ton To 120 Ton QS-YBJ. Double Ended shear beam load cell weight sensor 10 ton load cell 20 Ton To 120 Ton QSF can help companies stand out in a fiercely competitive environment and become the industry leader in one fell swoop. So, shake hands with us, expand your business, and increase your clientele.
Model Number: | QS-YBJ | Place of Origin: | Zhejiang, China |
Brand Name: | Santwell | Usage: | PRESSURE SENSOR |
Theory: | Resistance Sensor | Output: | Analog SENSOR |
Description: | double ended beam load cell | Rated Load: | 20/30/40/50/60/80/120 |
Sensitivity: | 2.0000±0.002mv/v | Total Error: | ±0.02%F.S |
Creep(30 minutes): | ±0.02%F.S | Recommended Excitation Voltage: | 5V-18V(AC or DC) |
Maximum Excitation Voltage: | 24V(AC or DC) | Zero Balance: | ±1%F.S |
Insulation Impedance: | ≥5000MΩ | Safe Overload: | ±150%F.S |
UItimate Overload: | ±200%F.S | Application: | In the metallurgical industry metering equipment |
Technical Parameter | ||||
Rated Load | T | 20/30/40/50/60/80/120 | ||
Sensitivity | mV/V | 2.0000±0.002 | ||
Total Error | %F.S | ±0.02 | ||
Creep(30minutes) | %F.S | ±0.02 | ||
Recommended Excitation Voltage | V | 5 ~18 (AC or DC) | ||
Maximum Excitation Voltage | V | 24 (AC or DC) | ||
Zero Balance | %F.S | ±1 | ||
Input Impedance | Ω | 775±10 | ||
Output Impedance | Ω | 700±5 | ||
Insulation Impedance | MΩ | ≥5000 | ||
Safe Overload | %F.S | 150 | ||
Ultimate Overload | %F.S | 200 | ||
Operating Temperature Range | ℃ | (-30~+70) | ||
Compensated Temperature Range | ℃ | (-20~+60) | ||
Temperature Effect On Load | ℃ | ±0.02%F.S/10 | ||
Temperature Effect On Zero | ℃ | ±0.02%F.S/10 | ||
Construction | Alloy steel | |||
Protection Class | IP67&IP68 | |||
Citation | GB/T7551-2008/OIML R60 | |||
Mode of Connection | Input+E:Red Input-E:Black Output+S:Green Output-S:White |