Single Double Ended shear beam load cell weight sensor 15 Ton Weight QS-VIS is created with fashionable design idea. After Single Double Ended shear beam load cell weight sensor 15 Ton Weight QS-VIS launching into the market, we have gained a lot of support and praise. Most customers think that this kind of products are in line with their expectations in terms of appearance and performance. Ningbo Santwell Import & Export Co., Ltd will strive toward excellence by building our working principles of guaranteeing quality for survival and seeking innovation for development, into everything we deliver. We are confident that we will overcome all the difficulties and obstacles to make a success in the end.
Model Number: | QS-VIS | Type: | Load Cell |
Place of Origin: | Zhejiang, China | Brand Name: | Santwell |
Description: | double ended beam load cell | Rated Load: | 15 T |
Sensitivity: | 2.0000±0.002mv/v | Total Error: | ±0.05%F.S |
Creep(30 minutes): | ±0.02%F.S | Recommended Excitation Voltage: | 5V-18V(AC or DC) |
Maximum Excitation Voltage: | 24V(AC or DC) | Zero Balance: | ±1%F.S |
Insulation Impedance: | ≥5000MΩ | Safe Overload: | ±150%F.S |
UItimate Overload: | ±200%F.S |
Technical Parameter | ||||
Rated Load | T | 15 | ||
Sensitivity | mV/V | 2.0000±0.002 | ||
Total Error | %F.S | ±0.05 | ||
Creep(30minutes) | %F.S | ±0.02 | ||
Recommended Excitation Voltage | V | 5 ~18 (AC or DC) | ||
Maximum Excitation Voltage | V | 24 (AC or DC) | ||
Zero Balance | %F.S | ±1 | ||
Input Impedance | Ω | 775±10 | ||
Output Impedance | Ω | 700±5 | ||
Insulation Impedance | MΩ | ≥5000 | ||
Safe Overload | %F.S | 150 | ||
Ultimate Overload | %F.S | 200 | ||
Operating Temperature Range | ℃ | (-30~+70) | ||
Compensated Temperature Range | ℃ | (-20~+60) | ||
Temperature Effect On Load | ℃ | ±0.02%F.S/10 | ||
Temperature Effect On Zero | ℃ | ±0.02%F.S/10 | ||
Construction | Alloy steel | |||
Protection Class | IP67&IP68 | |||
Citation | GB/T7551-2008/OIML R60 | |||
Mode of Connection | Input+E:Red Input-E:Black Output+S:Green Output-S:White |